Skip to content

Conversation

@preearor
Copy link
Contributor

#43

  • Support for / in handler name
  • Added test for the same
  • Updated to get the module name to check for builtin module even if customer gives handler name with (a.b.module_name)

By submitting this pull request, I confirm that you can use, modify, copy, and redistribute this contribution, under the terms of your choice.

Copy link
Contributor

@SukanyaHanumanthu SukanyaHanumanthu left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

LGTM!

Copy link
Contributor

@keshayad keshayad left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

Looks good


try:
if modname.split(".")[0] in sys.builtin_module_names:
if modname.split(".")[-1] in sys.builtin_module_names:
Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

It'd be good to cover this in the test suites too

@preearor
Copy link
Contributor Author

Raising another PR, to add test cases and revert the check for built-in module

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Labels

None yet

Projects

None yet

Development

Successfully merging this pull request may close these issues.

4 participants