20 changes: 1 addition & 19 deletions docs/build/phone.md
Original file line number Diff line number Diff line change
Expand Up @@ -30,24 +30,6 @@ You need a minimum version of the mobile operating software, called the *iOS*, t

* The developers maintain support for the current and one-level earlier *iOS*

### iPhone 16 and InPlay DASH pods

!!! warning "iPhone 16 and Omnipod DASH"
Some of the DASH pods produced in 2025 have different chips and firmware.

* These pods, which advertise a Bluetooth Device name of `InPlay BLE` and indicate `-Atlas` in small print on the paper pod cover are fully compatible with all iPhone models except iPhone 16
* Early reports indicate the `InPlay BLE` pods work fine with iPhone 17
* Although `InPlay` pods do work with the 16 you may notice some communication issues
* It can take many attempts to get the pod to initially connect when pairing; just keep hitting retry
* Once the pod disconnects itself from the phone Bluetooth, the phone is slow to reconnect the pod to the *Loop* app
* Pod firmware initiates the disconnect 3 minutes after the last message exchange
* With other models, the reconnect happens in about 1 sec
* With iPhone 16, this can take many seconds and sometimes a few minutes
* When the pod is not connected, neither automatic nor manual commands can be sent to the pod to modify insulin delivery
* No solution to this issue is known

> DASH pods that advertise a Bluetooth Device name of `TWI Board` and indicate `-SAW` in small print on the paper pod cover are fully compatible with all phones included the iPhone 16.

### Compatible Device

All the devices listed below are currently compatible with Loop. They are separated by the available *iOS* for the phone.
Expand All @@ -58,7 +40,7 @@ These phones require *iOS* 26 and `Loop version 3.8.x` or newer

These phones require *iOS* 18 and are compatible with *iOS* 26

- iPhone 16, all variants
- iPhone 16, all variants (phone is compatible but see [InPlay DASH pod](../faqs/omnipod-faqs.md#iphone-16-and-atlas-or-inplay-dash-pods){: target="_blank" } warning)

These phones are compatible with *iOS* 17, 18 and 26

Expand Down
8 changes: 6 additions & 2 deletions docs/build/pump.md
Original file line number Diff line number Diff line change
Expand Up @@ -10,7 +10,7 @@
- If you have a Medtronic pump, check the [Medtronic Pump Version](#check-medtronic-pump-version) list to ensure compatible model/firmware
- If you use [Omnipod](#omnipod-pumps) - check which kind
- If you use [Dana](#sooil-dana-pumps) - check which kind
- If you use [Medtrum Nano](#medtrum-touchcare-nano) - Check which loop version
- If you use [Medtrum Nano](#medtrum-nano) - Check which loop version

!!! question "FAQs"
- **"How can I find a compatible Medtronic pump?"** Refer to [Finding a Medtronic Pump](#finding-a-medtronic-pump).
Expand Down Expand Up @@ -226,7 +226,11 @@ The DanaRS was first released in 2002, with firmware version v1 which is not sup
## Medtrum Nano

!!! warning "You must build feat/dev-medtrum branch to use Medtrum patch pumps"
The Medtrum patch pump is in feat/dev-medtrum (as of version v3.9.0) and is experimental as of now
The Medtrum patch pump is in feat/dev-medtrum (as of version v3.9.0) and is experimental as of now.

**Be very careful running this. The initial version had a bug where a delivered bolus was not always recorded properly. This is just one example of why only experts should volunteer to test experimental code.**

Follow along in the [zulipchat Medtrum channel](https://loop.zulipchat.com/#narrow/channel/144182-development/topic/Medtrum.20Nano.20-.20pumps.20for.20development.20use/with/481836247).

!!! info "All versions are supported!"
Both 200U (MD0201 & MD8201) and 300U (MD8301) version are supported with the correct version of the *Loop* app.
Expand Down
7 changes: 2 additions & 5 deletions docs/build/rileylink.md
Original file line number Diff line number Diff line change
@@ -1,14 +1,11 @@
## Order a RileyLink Compatible Device

**Not needed for any pump that supports direct Bluetooth BLE commands**

* **Dana**
* **DASH**
**Not needed for any pump that supports direct Bluetooth BLE commands such as Dana, DASH and Medtrum**

**Required when using an older Medtronic pump or Omnipod Eros pods**

!!! info "Time Estimate"
- 0 minutes if you plan to use a Dana pump or a DASH Omnipod pump - you don't need one
- 0 minutes if you plan to use a pump that supports direct BLE communication - you don't need one
- 15-20 minutes to read about RileyLink compatible devices
- 15 minutes to order a device

Expand Down